messenger

Chat Face

zalo

Chat Zalo

phone

Phone

Call: 0386365636 - Mr.Sơn
Quay lại

Office equipment, IT, telecom devices.

Components and accessories for electric vehicles

Fluke Fluke-115/APAC Multimeter (True RMS)

Status: Còn hàng

Trademark: FLUKE

Code: FLUKE-116/APAC

6 View

Contact
  • Digital multimeter specifically designed for HVAC (Heating, Ventilation, and Refrigeration) applications.

  • Integrated microamp temperature and current measurement functions – ideal for testing HVAC sensors.

  • Allows measurement of AC/DC voltage, current, resistance, capacitance, frequency, and circuit continuity .

  • The LoZ (Low Impedance) function helps eliminate phantom voltage, ensuring more accurate measurement results.

  • High accuracy , large and clear numbers displayed on a backlit LCD screen.

  • Includes value hold function, MAX/MIN/AVG, and automatic shutdown .

  • The rubber outer casing provides shock protection and anti-slip properties , with a professional design and a secure grip.

  • Genuine Fluke product from the USA , meeting international safety standards CAT III 600V.

  • Suitable for HVAC technicians, industrial maintenance, and electrical/electronics engineers .

  • The APAC (Asia-Pacific) version comes with all accessories and documentation in English/Chinese.

Go to cart
Present

Contact support for detailed quote: Hotline: 0386365636

The Fluke 116 multimeter is a specialized measuring instrument designed specifically for HVAC (heating, ventilation, and air conditioning) applications, offering a range of professional measurement features.

FLUKE-116/APAC Multimeter (FLUKE-116)

 

Specifications

Measurability

  • DC voltage: 600mV to 600V with an accuracy of ±0.5%

  • AC voltage: 600mV to 600V with an accuracy of ±1%.

  • Current: 600µA with an accuracy of ±1.5%

  • Resistance: 600Ω to 40MΩ

  • Capacitance: 1000nF to 9999µF

FLUKE-116/APAC Multimeter (FLUKE-116)

Special features

  • True RMS technology enables accurate measurements.

  • The integrated thermometer measures temperatures from -40°C to 400°C.

  • The VoltCheck™ function automatically selects the AC/DC measurement range.

  • Measure microamps to test the fire sensor.

FLUKE-116/APAC Multimeter (FLUKE-116)

Design and safety of the FLUKE-116/APAC (FLUKE-116) multimeter

Design

  • Large LCD screen with white LED backlight.

  • Compact design for one-handed operation.

  • Durable, impact-resistant casing

Safe

  • Meets CAT III 600V standards.

  • The LoZ function helps prevent errors caused by voltage spikes.

  • Compatible with ToolPak™ magnetic lanyards.

The device comes with a 12-month warranty and all standard accessories.

Specifications: Fluke 116 HVAC Multimeter with Temperature and Microamps

Specifications
The maximum voltage between any wire end and the ground wire.
   600 V
Overvoltage protection
   Maximum voltage 6 kV according to IEC 61010-1 600 V CAT III, Pollution resistance level 2
Screen
Digital:  6,000 counts, updated 4/second
Bar chart
   33 segments, updated 32 times/second.
Operating temperature
   -10 °C to +50 °C
Storage temperature
   -40 °C to +60 °C
Battery type
   9V alkaline battery, NEDA 1604A/IEC 6LR61
Battery life
   Typically 400 hours, without backlight.
Accuracy specifications
DC voltage in mV
Measurement range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% measurement] + [counts]): 0.5% + 2
DC V
Measurement range/Resolution:  6,000 V/0.001 V
Measurement range/Resolution:  60.00 V/0.01 V
Measurement range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% measurement] + [counts]): 0.5% + 2
Automatic voltage
Measurement range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0% + 3 (dc, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC voltage in mV 1 effective value
Measurement range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0% + 3 (dc, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC voltage V1 effective real
Measurement range/Resolution:  6,000 V/0.001 V
Measurement range/Resolution:  60.00 V/0.01 V
Measurement range/Resolution:  600.0 V/0.1 V
Accuracy:  1.0% + 3 (dc, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Measurement range:  600 Ω
Resolution:  1 Ω
Accuracy:  Audible alarm: On < 20 Ω, Off > 250 Ω; detects open circuit or short circuit within 500 μs or longer.
Resistor
Measurement range/Resolution:  600.0 Ω / 0.1 Ω
Measurement range/Resolution:  6,000 kΩ / 0.001 kΩ
Measurement range/Resolution:  60.00 kΩ / 0.01 kΩ
Measurement range/Resolution:  600.0 kΩ / 0.1 kΩ
Measurement range/Resolution:  6,000 MΩ / 0.001 MΩ
Accuracy:  0.9% + 1
Measurement range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  1.5% + 2
Diode testing
Measurement range/Resolution:  2,000 V/0.001 V
Accuracy:  0.9% + 2
Capacitance
Measurement range/Resolution:  1000 nF/1 nF
Measurement range/Resolution:  10.00 μF/0.01 μF
Measurement range/Resolution:  100.0 μF/0.1 μF
Measurement range/Resolution:  9999 μF/1 μF
Measurement range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Measurement range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
Low impedance capacitance LoZ
Measurement range:  1 nF to 500 μF
Accuracy:  Typically it's 10% + 2
Temperature 2 (Type K thermocouple)
Measurement range/Resolution:  -40 °C to 400 °C/0.1 °C
Accuracy:  1% + 10 2
Measurement range/Resolution:  -40°F to 752°F/0.2°F
Accuracy:  1% + 18 2
AC current intensity in microamperes (45 Hz to 500 Hz)
Measurement range/Resolution:  600.0 μA/0.1 μA
Accuracy:  1.5% + 3
DC current intensity in microamperes
Measurement range/Resolution:  600.0 μA/0.1 μA
Accuracy:  1.5% + 3
Hz (V or A input) 2
Measurement range/Resolution:  99.99 Hz/0.01 Hz
Measurement range/Resolution:  999.9 Hz/0.1 Hz
Measurement range/Resolution:  9.999 kHz/0.001 Hz
Measurement range/Resolution:  50.00 kHz/0.01 Hz
Accuracy:  0.1% + 2

Note:
1) All AC voltage measurement ranges except Auto-V/LoZ are indicated from 1% to 100% of the measurement range. Auto-V/LoZ is indicated from 0.0 V.
2) Temperature error (accuracy) does not include thermocouple probe error.
3) Coupled frequency of AC current, 5 Hz to 50 kHz for AC voltage. Coupled frequency of DC current, 45 Hz to 5 kHz for AC current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

General mechanical and technical specifications
Size
   167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Mass
   550 g
Guarantee
   3 years